Home Schedules Standards of Input Output Norms (SION) C. Engineering Products This
Forgot password New User/ Regiser ⇒ Register to get Live Demo
Current Transformers above 72.5 KV upto & including 145 KV (Outdoor Type)(Containing 120 kg of item 1, 45 kg of item 2, 50 kg of item 3, 90 kg & 45 kg of item 5 and 185 or 222 Ltr. of item 6) - Standards of Input Output Norms (SION) - C. Engineering ProductsExtract C183 Current Transformers above 72.5 KV upto including 145 KV (Outdoor Type)(Containing 120 kg of item 1, 45 kg of item 2, 50 kg of item 3, 90 kg 45 kg of item 5 and 185 or 222 Ltr. of item 6) 1 No. 1 CRGO Steel Laminations/ Sheets/ Coils with insulating coating of inorganic/ organic material OR 138 kgs 1 Nickel Iron Magnetic Strips/ Sheets/ Coils 132 kgs 2 Copper Winding Wires/ Strips/ Wire Bars/ Wire Rods/ Cathodes 45.45 kgs 3 Electrical Grade Insulating paper 55.0 kgs 4 Porcelain Insulator 1 No. 5 Mild Steel Sheets/ Coils OR 99 kgs 5 Aluminium Sheets/ Plates/ Ingots 47.25 kgs 6 Transformer Oil OR 194.25 Litres 6 Transformer Oil Base Stock 233.10 Litres
|