Transformers (Aluminium Wound) upto & including 100 KVA 3 Phase, Oil Cooled - Standards of Input Output Norms (SION) - C. Engineering ProductsExtract C325 Transformers (Aluminium Wound) upto including 100 KVA 3 Phase, Oil Cooled 1 No. 1 CRGO Silicon electrical steel sheets/coils or 2.64 kgs/KVA CRGO Transformers-Lamination Net to Net 2 Aluminium Winding Wires/ strips/ ingots/ wire bars 1.12 kg/KVA 3 Transformer Oil OR 3.57 kgs/KVA 3 Transformer Oil Base Stock 3.93 kgs/KVA 4 Pre-compressed press board 0.13 kgs/KVA 5 Phenolic Resin bonded paper 0.015 kgs/KVA 6 Motorised Off-load/ On-load Tap Changer/ Switch 1 No. (Net to net) 7 Pre-pressed boards/ moulded components 1 No. (Net to net) Note 1. In case the transformer are exported without the M.S. Tank and Transformer Oil, then the input item No. 3 i.e. Transformer Oil or Transformer Oil Base Stock, shall not be permitted. Note 2. If in the export product, the core is of amorphous electrical steel, then import of 2.6 kg/KVA of "amorphus electrical steel sheet/ coil may be allowed in place of import item No. 1 i.e. CRGO Steel laminations/ Sheets/ Coil allowed in this norm
|