Home Schedules Standards of Input Output Norms (SION) C. Engineering Products This
Forgot password New User/ Regiser ⇒ Register to get Live Demo
Hermetically sealed compressors for air-conditioner using R 22 refrigerant gas of different capacities - Standards of Input Output Norms (SION) - C. Engineering ProductsExtract C1745 Hermetically sealed compressors for air-conditioner using R 22 refrigerant gas of different capacities 1 No. 1 Components Net to net basis except upper and lower housing 2 a) CRNGO Steel upto 3500 Kcal/hr 0.0032 Kg/Kcal b) More than 3500 Kcal/hr 0.0024 Kg/Kcal 3 a) Copper Wire upto 3500 Kcal/hr 0.0005 Kg/Kcal b) More than 3500 Kcal/hr 0.0004 Kg/Kcal 4 a) Music Wire Upto 3500 Kcal/hr 0.000016 Kg/Kcal b) More than 3500 Kcal/hr 0.000011 Kg/Kcal 5 a) Refrigeration Oil Upto 3500 Kcal/hr 0.0003 Kg/Kcal b) More than 3500 Kcal/hr 0.0002 Kg/Kcal 6 HR non alloy steel sheet/coils 1.28 Kg/Kg content 7 EC grade aluminium ingot 1.08 Kg/Kg content
|